Automotive wire gauge calculator

Find the smallest copper wire (AWG) that carries your current without too much voltage drop or heat.

AWGmm²Max ampsMax fuseΩ per 1000 ft

Max amps are conservative values for copper chassis wire bundled in a harness at room temperature. Engine-bay wire is derated 20%. The recommended fuse is the smallest standard size at or above your load (with a 25% margin for continuous duty) and never above the wire’s rating. Max fuse is the largest standard size at or below the wire’s rating. Always fuse as close to the power source as possible. Battery cables, starters and alternators should follow the manufacturer’s recommendation.

About this tool

Find the smallest copper wire gauge (AWG) for your current and run length with acceptable voltage drop and heat.

Advertisement

Frequently asked questions

What voltage drop is acceptable in a car?

3% (about 0.4 V on a 12 V system) is a common target for most circuits, and less for sensitive electronics.

Do I count both directions of the circuit?

Yes. Use the total round-trip length of the positive and ground wires.